TARTARINI Tartarini, Tartarini TARTARINI
Types SR, SRS, SRII, SRSII, and STP
Silencers for Pressure Regulator Installations
Introduction
Silencers are noise reduction system
devices which are commonly installed in a
regulator as a remedy for noise pollution.
Available Configurations
Type SR:
This silencer isftted near the regulator
shutter and is highlyeffcient up to a
theoretical speed of 80 m/s calculated at
the outlet flange.
Higher than this speed, noise may be
generated by the expansion cone, usually
installed downstream of the regulator,
and may require an additional noise
reduction solution.
Type SRII:
The SRII silencer is the next generation
of type SR and is used in case of extreme
service conditions (dirty gas, high
pressure drops, and high gas velocities).
Noise characteristics are very similar to
the standard SR.
Type SRS and SRSII:
The SRS consists of an SR silencer plus a
widened outlet flange in which a second
silencer isftted.
The SRSII consists of an SRII silencer
plus a widened outlet flange in which a
second silencer is ftted.
In bothconfgurations the second
silencer has an initial multi-path section
and a second multi-stage section.
These silencers are highlyeffcient under
all operating conditions and are not
limited by the theoretical speed on the
regulator outlet flange.
Type STP:
Usually used downstream of SRS or SRSII
silencers but can also be combined with a
SR silencer.
Overall reduction in noise level is the
sum of the reduction produced by SR/
SRII or SRS/SRSII plus the STP induced
reduction. The type STP silencer consists
of one or more porous channels clad with
soundproofng material.
Sound penetrates inside the soundproof
layer and is transformed into heat byfriction of the gas flow.
The silencer isftted in the pipe and is
secured with two flanges.
Two types of silencers are available:
• STP10 10 dB (A) attenuation,
approximate length of 1 m
• STP10 20 dB (A) attenuation,
approximate length of 2 m
For full details consult the documentation available on our website:
www.Tartarini-Naturalgas.com
TARTARINI, Tartarini Emerson
FL Series
Pilot-Operated Pressure Reducing Regulators
Introduction
The FL Series regulators are accurate
pilot-operated, pressure balanced,
soft seated regulators designed for
high-pressure transmission/city gate,
large capacity distribution systems, and
power plant feeds.
The FL Series provides smooth and quiet
operation, tight shutoff, and long life.
The FL Series is in conformity with the
Pressure Equipment Directive PED
2014/68/UE and isclassifed under
Category IV.
Available Configurations
Type FL:
High Pressure Regulator or Monitor
Type MFL:
High Pressure Regulator + Monitor
Type BFL:
High Pressure Regulator + Shutoff
All FL type regulators are available with
or without:
Type SR / SRII: Silencer
Type SRS / SRSII: Silencer with widened
outlet flange
A widened outlet version without built-in
silencer is also available.
Body Sizes
FL Series:
DN 25, 40, 50, 65, 80, 100, 150*, 200*,
and 250*
(NPS 1, 1-1/2, 2, 2-1/2, 3, 4, 6*, 8*, and 10*)
FL Series with Type SRS / SRSII Silencer
or Widened Outlet:
DN 25 x 100, 40 x 150, 50 x 150, 65 x 200,
80 x 250, 100 x 250, 150 x 300*, and
200 x 400*
(NPS 1 x 4, 1-1/2 x 6, 2 x 6, 2-1/2 x 8, 3 x 10,
4 x 10, 6 x 12*, and 8 x 16*)
* These sizes are not available in MFL and BFL
confgurations.
End Connection Styles
CL300, and CL600
Inlet Pressure Ranges
Allowable Pressure: Up to 100 bar
Inlet Pressure Range: 1 to 100 bar
Outlet Pressure Range
0.5 to 80 bar
Minimum Operating Differential
Pressure
0.5 bar
Accuracy Class
Up to ±1%
Lock-Up Pressure Class
Up to +5%
Class of Lock-Up Pressure Zone
Up to 5%
Built-In Shutoff Valve
Independent Pneumatic Control
Manual Reset
Accuracy Group: Up to ±1%
Response Time: ≤1 s
Temperature Capabilities
Standard Version:
Working: -10° to 60°C
Low Temperature Version:
Working: -20° to 60°C
Approximate Weights
(Including Pilot)
31 to 1190 kg
For full details consult the documentation available on our website:
www.Tartarini-Naturalgas.com
• No Atmospheric Bleed
• Quiet Operation
• Control Accuracy
• Versatility
• Easy In-Line Maintenance
• Tight Shutoff
• High Capacity
• In-Service Travel Indicator